Mounting the Access Point
Figure 2-11
1
Metal strap open space
Do not place the metal straps in the large open area between the pole clamp bracket and the strap brackets
Caution
because this does not properly secure the access point.
Position the pole clamp bracket on the pole as needed before tightening the metal bands.
Step 4
Note
Tighten the metal bands using the banding strap tool (BAND IT) (Cisco AIR-BAND-INST-TL=) by
Step 5
following the operating instructions in the box with the tool. Ensure that the metal bands are as tight as
possible.
Place the mounting bracket onto the pole clamp bracket support bolt (see
Step 6
For vertical poles, position the mounting bracket as shown in
Step 7
poles, rotate the mounting bracket 90
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-22
Metal Strap Open Space for 3.5 inch (8.9 cm) and Smaller Poles
When the metal bands are tightened to the full tension, the pole clamp bracket cannot be adjusted
unless the metal bands are cut or disassembled.
Figure
o
from the position shown in
Chapter 2
Installing the Access Point
Figure
2-12).
2-12. For horizontal streetlight
Figure
2-12.
OL-24247-01