Connecting a Fiber-Optic Cable to the Access Point
Loosen the round end of the liquid-tight connector by turning counterclockwise, but do not remove (see
Step 6
Figure
Figure 2-33
1
Thread end
Step 7
Carefully screw the threaded end of the adapter into the access point and hand-tighten.
Step 8
Use an adjustable wrench, the 22 mm socket, or the Sealcon S-2200-WR wrench to tighten the threaded
end of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 9
Carefully remove approximately 1 to 2 ft (30.5 cm) of the external jacket from the fiber-optic cable,
exposing the inner strand.
Carefully insert the fiber-optic LC cable connector into the rounded end of the liquid-tight adapter (see
Step 10
Figure
Wrap excess fiber-optic cable around the take-up reels in a figure eight (8) pattern.
Step 11
Insert the fiber-optic LC cable connector into the SFP module.
Step 12
Step 13
Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs
(3.66 to 4.34 Nm).
Close the hinged cover (see the
Step 14
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-44
2-33).
Liquid -Tight Adapter
2-33), and push through the adapter.