Toshiba B-EX4 SERIES Maintenance Manual page 98

Hide thumbs Also See for B-EX4 SERIES:
Table of Contents

Advertisement

5. SYSTEM MODE
Initial parameter values when turning the power on
ISSUE COUNT
PRINT SPEED
SENSOR
TYPE
LABEL LEN.
PAPER
Supplementary explanation:
Each fine adjustment parameter is effective for test print. However, the X-coordinate fine adjustment
is excluded.
When an error occurs during a test print, the error message is displayed and printing is stopped. The
error LED turns on and the online LED turns off.
The error is cleared by pressing the [CANCEL] key/[ENTER] key and the display shows the test print
menu. The error LED turns off and the online LED turns on. Printing is not automatically resumed
after the error is cleared.
The label size greater than the image buffer length cannot be designated. If it is designated, the
printer prints in the image buffer length then stops, or the printer stops because of an error.
When the transmissive sensor is selected, the gap between labels should be 3 mm.
For B-EX4, the print speed "10 ips" is not supported for printing with the rotary cutter. If "10 ips" is specified
when the rotary cutter has been installed, the print speed is corrected from 10 ips to 8 ips, regardless of the
cut designation.
For B-EX4T1-G, if less than 15.0 mm and 30.0 mm of the label pitch is specified for printing at 3 ips and 6
ips, respectively, an issue without a cut is performed.
For B-EX4T1-T, if less than 15.0 mm, 25.0 mm, 38.0 mm of the label pitch is specified for printing at 3 ips, 5
ips, and 8 ips, respectively, an issue without a cut is performed.
1 piece
203dpi 6"/sec
305dpi 5"/sec
Transmittive sensor
Thermal transfer
Batch issue
76mm
Enable paper feeding
5-50
EO18-33027