5. SYSTEM MODE
Print condition:
Label length
Print method
Sensor type
Speed
Issuing number
Issuing mode
Other
<< COUNTER >>
Item
Count condition
TOTAL FEED
Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse
feed operation.)
When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.
FEED
Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse
feed operation.)
When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.
FEED1
FEED4
The label historical distance.
PRINT
Counts while printing. (Counting is not performed during reverse feed operation.)
B-EX4T1-G:
When the power is off, the print distance of 8.2 m or less is rounded down and backed up.
B-EX4T1-T:
When the power is off, the print distance of 5.5 m or less is rounded down and backed up.
PRINT1
PRINT4
The historical print distance.
CUT
Every cut operation is counted.
When the power is off, a cut count of 31 or less is rounded down and backed up.
HEAD U/D
Counts head up/down operations using the ribbon saving solenoid.
operations is counted as one.)
When the power is off, an up/down count of 31 or less is rounded down and backed up.
RIBBON
Counts when the ribbon motor is driven to feed a paper or print. (Counts also during a reverse feed
operation.)
For B-EX4T1-G:
When the power is off, a drive time of 32 seconds or less is rounded down and backed up.
For B-EX4T1-T:
When the power is off, a drive time of 27 seconds or less is rounded down and backed up.
SOLENOID
Counts when the ribbon saving operation is performed.
For B-EX4T1-G:
When the power is off, a drive time of 32 seconds or less is rounded down and backed up.
For B-EX4T1-T:
203dpi
305dpi
Content
Total label distance covered (cannot be
cleared)
Label distance covered
Label distance covered historical
Print distance
Print distance historical
Cut count
Head up/down count
Ribbon motor drive time
Head-up solenoid drive time
490mm
Setting by user
Non
6ips
5ips
1 piece
Setting by user
No mount winding motor
Range
0.0
0.0
0.0
0.0
0.0
0
0
0
0
5-6
5.3 SELF-DIAGNOSTIC TEST
3200.0 km
3200.0 km
3200.0 km
200.0 km
3200.0 km
1000000
2000000
(Combination of up and down
2000 Hour
1000 Hour
EO18-33027

Hide quick links: