5. SYSTEM MODE

5.8 RAM CLEAR

Outline of RAM Clear
In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible.
After replacing the print head, ribbon motor, or platen, perform maintenance clear.
The RAM Clear menu contains the following:
MENU ITEM
System Mode / SYSTEM MODE
<6>RAM
Clear Disable / NO RAM CLEAR

Counter clear / MAINTE.CNT CLEAR

Parameter clear / PARAMETER CLEAR

5.8.1 No RAM clear / NO RAM CLEAR

This is a selection to prevent wrong user operation.
5.8.2 Counter clear / MAINTE.CNT CLEAR
It clears maintenance counter, like label distance covered etc.
Initial value after maintenance counter clear
Item
Label distance covered
Print distance
Cut count
Head up/down count
Ribbon motor drive time
Head-up solenoid driver time
RS-232C hardware error count
System error count
Momentary
power
count
/ <6>RAM CLEAR
All counter / ALL COUNTER
Label distance covered / FEED
Print distance / PRINT
Cut count / CUT
Others / OTHER
QM type / QM TYPE
JA type / JA TYPE
CN type / CN TYPE
Initial value
interruption
0 km
0 km
0
0
0 hours
0 Hours
0
0
0