Hot Replacement - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

19. From the OS, execute the cfgadm -c configure TAPE_Ap_Id command to
configure the tape drive unit to the domain.
# cfgadm -c configure c0::rmt/0
20. From the OS, execute the cfgadm -a command to verify that the status of
CD-RW/DVD-RW drive unit and the tape drive unit has changed from
"unconfigured" to "configured."
#
cfgadm -a
Ap_Id
c0::dsk/c0t4d0 CD-ROM connected
c0::rmt/0
21. Close the door on the server, and lock it.
14.3

Hot Replacement

The procedure is as follows.
1. Unlock and open the appropriate door on the server.
For details, see
Caution – Before touching FRU or the dummy (filler) unit, see
"Antistatic Precautions" on page 1-6
Failure to do so might result in serious damage to operating domains.
2. Stop all connection to the target CD-RW/DVD-RW drive unit.
3. Turn off power to the relevant domain.
From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -d command.
The OS shutdown processing is executed for the relevant domain, and then the
power-off processing is executed.
4. Detach the target CD-RW/DVD-RW drive unit from the port.
From a terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p <port no.> command.
Type
Receptacle Occupant
:
tape
connected
:
Chapter
5.
and be sure to wear the antistatic wrist strap.
Chapter 14
Condition
configured
unknown
configured
unknown
CD-RW/DVD-RW Drive Unit Replacement
Section 1.4,