LED Display That Should Be Checked When a FRU Is Replaced (Common) (Continued)
TABLE 2-11
LED
Display and meaning
CHECK
Indicates either that the unit contains an error or that the unit is a target device for replacement.
(amber)
Lit
Blinking (*1) Indicates that the FRU is to be replaced.
Off
Note – *1)If the maintenance target component is indicted by a blinking CHECK
LED, the LED may be called a locater.
Status Display of LEDs Defined Individually for Each FRU
TABLE 2-12
LED
FRU
Type
XSCFU
READY
CHECK
ACTIVE
2-32
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Indicates that an error has been detected in the hardware of the FRU. (For an
HDD, the LED is lit according to the instruction from the software or
middleware.)
Indicates that the state of the FRU is normal.
Display
Lit (green)
Blinking
(green)
Off
Lit (amber)
Blinking
(amber)
Off
Lit (green)
Off
Meaning
Indicates that the XSCFU is in use. In this state, the
XSCFU cannot be removed (cannot be replaced).
Indicates that the XSCFU is being initialized.
Indicates that the XSCFU can be replaced.
Indicates that an error was detected in the XSCFU.
However, this LED remains on for a few minutes
immediately after power-on (until the start of
initialization). It does not indicate an error during that
time.
Indicates that the XSCFU is a replacement target.
Indicates that the XSCFU is in the normal state.
Indicates that the XSCFU is in use (active).
Indicates that the XSCFU is on standby.