Addition; Active Addition - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

Some FRUs can be actively added or actively deleted:
Active addition or removal of a CMU or IOU is possible using the DR function.
Maintenance or addition of a DIMM module involves removing or installing a
CMU.
Active addition or removal of PCI cards (including link cards) is possible using
the PHP function.
Active addition of TAPEUs is possible
Caution – For deletion, a filler panel (
slot. Without filler panels, the system might overheat.
TABLE 25-1
Slot location
CMU
IOU
PCI
25.1

Addition

Some steps for adding a FRU are the same as for replacing a FRU. For more details,
refer to the appropriate chapter on FRU replacement.
25.1.1

Active Addition

First, select a unit to be added as described below.
1. Log in to the XSCF.
2. Execute the addition command (addfru).
XSCF> addfru
3. When the following addition menu is displayed, select the type of FRU to be
added.
25-2
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Filler Panels
) must be installed in the empty
TABLE 25-1
Filler panel name
CMU filler panel
IOU filler panel
PCI filler panel