7. From the OS, execute the cfgadm -c unconfigure DVD_Ap_Id command to
unconfigure the CD-RW/DVD-RW drive unit from the domain.
# cfgadm -c unconfigure c0::dsk/c0t4d0
8. From the OS, execute the cfgadm -a command to verify that the status of tape
drive unit and CD-RW/DVD-RW drive unit has changed from "configured" to
"unconfigured."
# cfgadm -a
Ap_Id
c0::dsk/c0t4d0
c0::rmt/0
9. Detach the target tape drive unit from the port.
From the terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p port no. command.
10. Confirm that the target tape drive unit is unconfigured from the domain.
From XSCF, execute cfgdevice -l to confirm that the relevant port is not
displayed in the current connection.
11. Connect the clip of the antistatic wrist strap and of the antistatic mat to the
server grounding port. See
12. Ensure that the metallic underside of the wrist strap is in direct contact with
your skin. The wrist strap should be snug around the wrist so that it does not
rotate. See
Caution – Before handling FRUs, be sure to connect the clip of the antistatic wrist
strap and of the antistatic mat to the server grounding port, and attach the band of
the wrist strap to one of your wrists. Place the FRUs on the grounded antistatic mat.
Failure to take these antistatic measures might result in serious damage.
15-6
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Type
Receptacle
:
CD-ROM connected
tape
connected
:
Section 1.4, "Antistatic Precautions" on page
Section 1.4, "Antistatic Precautions" on page
Occupant
Condition
unconfigured
unknown
unconfigured
unknown
1-6.
1-6.