Dell PowerVault ML6010 Troubleshooting Manual page 212

Tape library
Hide thumbs Also See for PowerVault ML6010:
Table of Contents

Advertisement

TapeAlert Flag Descriptions
25
Multi-port
W
interface error
on a primary
port
26
Cooling fan
W
failure
27
Power supply
W
failure
28
Power
W
consumption
29
Drive
W
preventive
maintenance
required
30
Hardware A
C
31
Hardware B
C
32
Primary
W
file:///T|/htdocs/stor-sys/ML6000/en/html/appb.htm[9/17/2012 1:51:07 PM]
A redundant interface port on the tape drive has failed.
A tape drive cooling fan has failed.
A redundant power supply has failed inside the tape drive enclosure. Check
the enclosure user's manual for instructions on replacing the failed power
supply.
The tape drive power consumption is outside the specified range.
Preventive maintenance of the tape drive is required. Check the tape drive
user's manual for device-specific preventive maintenance tasks or call the
tape drive supplier help line.*
The tape drive has a hardware fault:
1
Eject the tape or magazine.
2
Reset the drive.
3
Restart the operation.
The tape drive has a hardware fault:
1
Turn the tape drive off and then on again.
2
Restart the operation.
3
If the problem persists, call the tape drive supplier help line.*
The tape drive has a problem with the host interface:
which will be
resolved by
a retension
cycle.
Failure of
one interface
port in a
dual-port
configuration
(for
example,
Fibre
Channel).
Fan failure
inside tape
drive
mechanism
or tape drive
enclosure.
Redundant
power
supply unit
failure inside
the tape
drive
enclosure or
rack
subsystem.
Power
consumption
of the tape
drive is
outside
specified
range.
The drive
requires
preventative
maintenance
(not
cleaning).
The drive
has a
hardware
fault that
requires
reset to
recover.
The drive
has a
hardware
fault that is
not
read/write
related or
requires a
power cycle
to recover.
The drive