4-36 Configuring Your Server

Check Consistency

1.
Run LSI Logic Software RAID Setup Utility.
2.
Select "Check Consistency" from the TOP menu.
The "Logical Drives" screen appears.
3.
Move the cursor onto the logical drive to be checked, and press Space to select it.
4.
When logical drive has been selected, press F10 to start consistency check.
5.
A confirmation screen for execution appears. Select "Yes".
The consistency check starts.
When the progress bar in the "Check Consistency Progress" screen indicates 100%, the
consistency check is completed.
6.
Press Esc to return to the TOP menu and exit LSI Logic Software RAID Setup Utility.
IMPORTANT:
Be sure to execute Check Consistency after creating configuration.
Check Consistency has two modes: "check and recover" and "check