General Description - NEC Express5800/120Rg-1 User Manual

Nec servers user's guide
Hide thumbs Also See for Express5800/120Rg-1:
Table of Contents

Advertisement

STATUS LED
Description
indication
On (green)
The server is operating normally.
Flashing
The server is operating with the
(green)
memory or CPU in degraded
state.
An uncorrectable memory error
has often occurred.
Off
The power is off.
POST is in progress.
A CPU error occurred. (IERR)
A CPU temperature alarm was
detected.
A timeout occurred when the time
set for the watchdog timer arrived.
A CPU bus error occurred.
A memory dump request is made.
On (amber)
A temperature alarm was detected.
A voltage alarm was detected.
The power supply units failed.
Flashing
A fan alarm was detected.
(amber)
A temperature warning was
detected.
A voltage warning was detected

General Description 2-13

Procedure
Identify the device in degraded state
by using the BIOS setup utility
"SETUP," and replace it as soon as
possible.
Wait for a while. The STATUS LED
turns green when POST is completed.
Turn the power off and then turn it on.
If the POST screen displays an error
message, take notes of the message,
and contact your sales representative.
Wait until the memory dump is
completed.
Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS LED indication does
not change when the fans are normal,
contact your sales representative.
Contact your sales representative.
Check if the fan units are firmly
connected.
If the STATUS LED indication does
not change when the fans are normal,
contact your sales representative.
Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS LED indication does
not change when the fans are normal,
contact your sales representative.
Contact your service representative.

Advertisement

Table of Contents
loading

Table of Contents