(2) IH error
Checking timing
Power ON
In warming up
Detecting 40°C
In warming up
Detecting 40°C
During ready status
During ready status
During printing
At Energy Saving
Mode
(2) IH error
Initial abnormality:
13
CPU (IH) abnormality is not cleared.
IH power voltage abnormality:
The input voltage becomes above 20% (approx.) or below 20% (approx.) of the rated voltage.
IGBT high temperature abnormality:
Overheating of IGBT or short- or open-circuit of IGBT temperature-detecting sensor.
IH circuit abnormality:
Abnormality in IH circuit
IH coil abnormality:
Temperature-detecting sensor in IH circuit is abnormal, or IH coil is open-circuited or wrongly in-
stalled.
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
Error content
Initial abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
Normal
13 - 14
Port input value
H1ERR1
H1ERR2
L
L
L
L
L
H
H
H
L
L
L
H
H
H
L
L
L
H
H
H
H
L
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Error
Counter
code
C470
10
C470
11
C480
12
C490
13
C470
14
C480
15
C490
16
C470
17
C480
18
C490
19
-
-