A-2) Bypass misfeeding (
• During bypass feeding
Bypass feed clutch ON
Registration sensor ON
* Registration sensor is not turned ON in a fixed period of time (E120)
Bypass misfeeding (E120)
Bypass misfeeding symbol is displayed (
Copying operation is disabled
Solution: The bypass paper sensor is turned OFF by removing the paper from the bypass
tray.
A-3) Set key copy counter
• When the key copy counter (optional) is pulled out from the equipment which installs it:
"Set key copy counter" displayed
Copying operation disabled
• When the counter is pulled out during copying:
Copying is stopped when the key copy counter is pulled out.
B-1) Misfeed in equipment (
• Exit sensor detects jamming of the leading edge of paper.
Registration clutch ON
Exit sensor ON
If the exit sensor is not turned ON after
1.056 seconds,
Paper jam (E010) → The copying operation is stopped.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
)
)
↓ Less than 1.056 sec.
4 - 9
)
→
Registration clutch
Exit sensor
Timer
0
e-STUDIO350/352/353/450/452/453
ON
ON
.05sec.
Paper jam (E010)
Fig. 4-301