(D-2) Recovery blade
(1) Remove the cleaning blade (
11.6 (D-1)).
(2) Remove the recovery blade.
Notes:
1. When attaching the recovery blade, clean the
surface of the frame first. Be careful not to
deform the blade.
2. Attach the recovery blade while pushing it to
the step on the surface of the frame.
3. Press the stuck part with your finger to attach
the blade securely.
(D-3) Separation finger
(1) Remove the drum (
(2) Release the 3 separation fingers.
Notes:
1. When replacing the separation fingers,
make sure that the drum has been taken off
first since the fingers may scratch the drum
surface.
2. When the separation fingers have been re-
placed, check if their pressure movement is
normal by moving them with your fingers.
[E] Transfer / Separation charger
(E-1) Transfer / Separation charger
(1) Open the bypass tray, ADU and jam access
cover.
(2) Release the latches and take off the transfer
and separation chargers.
Note:
When installing the transfer and separation char-
gers, make sure not to deform the springs.