11.6 Disassembly and Replacement

[A] Cleaner unit
(1) Open the front cover, take off the toner bag
and front cover (
Chapter 2.5.1 [A]).
(2) Take off the developer unit (
12.5 [A]).
(3) Open the bypass unit, ADU and jam access
cover.
(4) Release the latch and remove the toner bag
full detection sensor-2.
(5) Loosen 2 screws and take off the cleaner
unit.
Notes:
1. Hold the cleaner unit which has been taken off
as shown in the figure.
2. Do not touch the drum surface.
[B]
Main charger
(B-1) Main charger
(1) Take off the cleaner unit (
[A]).
(2) Release the latch and pull out the main
charger to the direction of the arrow.
Note:
Be careful not to touch or scratch the drum
surface at this time.
(B-2) Main charger grid
(1) Push the terminal head at the front side and
remove the grid.
Note:
Do not touch the mesh area of the grid.