Cover open jam in the read ready status
1) Close the RADF jam access cover or the front cover if they are opened in the read ready status.
2) IIs the RADF jam access cover sensor working? (Perform the input check)
3) Check if the connector CN75 on the RADF board is disconnected from the RADF jam access
cover sensor or the harnesses are open circuited. Correct if any.
4) Replace the RADF jam access cover sensor.
5) Replace the RADF board.