5.3

Adjustment of Skew

Note:
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF. (See the Service Handbook of applicable equipment.) Also, the RADF position and
height shall be adjusted properly.
[A] Checking
Check the image using the chart (original) with vertical and horizontal lines in the following procedure.
(1)
Place the chart provided as an original with its face up on the original tray of the ADF, select [1
Sided -> 1 Sided] and press the [START] button.
(2)
Superimpose the chart on the copy and check the inclination of the copy image.
[B] Adjustment
(1)
Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 5-19 Chart (Original)
Fig. 5-20
5 - 9