3. Use the ▲ or ▼ key to select Serial communication and press ENTER.
The serial communication menu opens.
4. Use the ▲ or ▼ key to select Interface standard and press ENTER to toggle between [RS232] or [RS422]..
Default: [RS232]
Image 13-12

13.3.3 RS422 termination

What can be done?
When the interface standard is set to RS422, the last projector in a line should be RS422 terminated (ON position). All others in the
line should be in the OFF position.
How to set
1. Press MENU to activate the menus.
2. Use the ▲ or ▼ key to select Projector control and press ENTER.
3. Use the ▲ or ▼ key to select Serial communication and press ENTER.
The serial communication menu opens.
4. Use the ▲ or ▼ key to select RS422 termination and press ENTER to toggle between [On] or [Off].
Default: [On]
Image 13-15

13.4 Network

Overview
Introduction to a Network connection
DHCP setup
IP-address set up
Subnet-mask set up
Default Gateway set up
R59770179 FLM R22+ 15/03/2010
Image 13-13
Image 13-16
Image 13-14
Image 13-17
13. Projector control
149