Error
Description
code
7694
Red front DMD
temp high
7693
Red front DMD
temp open
7692
Red front DMD
temp short
7691
Green front
DMD temp low
7690
Green front
DMD temp high
7689
Green front
DMD temp
open
7888
Green front
DMD temp
short
7687
Blue front DMD
temp low
7686
Blue front DMD
temp high
7685
Blue front DMD
temp open
7684
Blue front DMD
temp short
7676
Front block
temp high
7675
Front block
temp open
7674
Front block
temp short
7672
Red block temp
high
7671
Red block temp
open
7670
Red block temp
short
7668
Green block
temp high
7667
Green block
temp open
7666
Green block
temp short
R59770179 FLM R22+ 15/03/2010
Error
Warning
Caused by
Yes
Yes
High temperature on red DMD
Yes
Yes
Temperature sensor on Red DMD
not connected
Yes
Yes
Temperature sensor on Red DMD
shorted
No
Yes
Low temperature on green DMD
Yes
Yes
High temperature on green DMD
Yes
Yes
Temperature sensor on green DMD
not connected
Yes
Yes
Temperature sensor on green DMD
shorted
-
Yes
Low temperature on blue DMD
Yes
Yes
High temperature on blue DMD
Yes
Yes
Temperature sensor on blue DMD
not connected
Yes
Yes
Temperature sensor on blue DMD
shorted
Yes
Yes
High temperature on front DMD
cooling block
Yes
Yes
Temperature sensor on front cooling
block not connected
Yes
Yes
Temperature sensor on front cooling
block shorted
Yes
Yes
High temperature on red DMD
cooling block
Yes
Yes
Temperature sensor on red DMD
cooling block not connected
Yes
Yes
Temperature sensor on red DMD
cooling block shorted
Yes
Yes
High temperature on green DMD
cooling block
Yes
Yes
Temperature sensor on green DMD
cooling block not connected
Yes
Yes
Temperature sensor on green DMD
cooling block shorted
21. Troubleshooting
Action
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer