Troubleshooting; Error Codes - Barco FLM R22+ User Manual

Hide thumbs Also See for FLM R22+:
Table of Contents

Advertisement

21. TROUBLESHOOTING

21.1 Error codes

Overview
When the error code is preceded by a '-' sign, then the error means a real error for the projector.
When the error code is preceded by a '+' sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
Description
code
1000
Wrong lamp
parameters
1017
1499
1498
1699
Formatter busy
1698
Formatter
address
1697
Formatter init
failed
1696
Formatter ctrl
init failed
1695
Red form. start
failed
1694
Green form.
start failed
1693
Blue form. start
failed
1692
Form.
PWRGood
2000
No lps detected
2001
Mains voltage
too low
2002
Lamp start
failed
2003
Main voltage
too high
2004
Lamp goes out
2005
Lamp stop
failed
2201
PFC start failed
2501
PFC start failed
2801
PFC start failed
2202
LPS start failed
2502
LPS start failed
R59770179 FLM R22+ 15/03/2010
Error
Warning
Caused by
-
Yes
Wrong lamp/ no communication
with lamp
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with red
formatter
-
Yes
no communication with green
formatter
-
Yes
no communication with blue
formatter
-
Yes
formatter 'Power Good' signal not
OK
-
Yes
no communication with lamp power
supply
-
Yes
mains voltage too low
-
Yes
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
-
Yes
mains voltage too high
-
Yes
-
Yes
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
21. Troubleshooting
Action
Check lamp type
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
Call qualified service engineer
Call qualified service engineer
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
213

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents