Barco FLM R22+ User Manual page 221

Hide thumbs Also See for FLM R22+:
Table of Contents

Advertisement

Error
Description
code
7980
Blue DMD
temp high
7978
Lamp temp
high
7976
SMPS HS temp
high
7974
Ambient temp
high
7973
Fan 1 voltage
low
7972
Fan 1 voltage
high
7971
Fan 2 voltage
low
7970
Fan 2 voltage
high
7969
Fan 3 voltage
low
7968
Fan 3 voltage
high
7967
Fan 4 voltage
low
7966
Fan 4 voltage
high
7965
Fan 5 voltage
low
7964
Fan 5 voltage
high
7963
Fan 6 voltage
low
7962
Fan 6 voltage
high
7959
Pump voltage
low
7958
Pump voltage
high
7957
30V voltage
low
7956
30V voltage
high
7955
VTEC voltage
low
R59770179 FLM R22+ 15/03/2010
Error
Warning
Caused by
Yes
Yes
high temperature on dmd
Yes
Yes
high temperature lamp
Yes
Yes
high temperature on smps
Yes
Yes
ambient temperature above
specification
Yes
Yes
voltage on fan group 1 too low (=
cathode fan)
-
Yes
voltage on fan group 1 too high
Yes
Yes
voltage on fan group 2 too low (=
anode fan)
-
Yes
voltage on fan group 2 too high
Yes
Yes
voltage on fan group 3 too low (=
engine fan)
-
Yes
voltage on fan group 3 too high
Yes
Yes
voltage on fan group 4 too low (=
cold mirror + head ex. fan)
-
Yes
voltage on fan group 4 too high (=
cold mirror + head ex. fan)
Yes
Yes
voltage on fan group 5 too low (=
mains input fan)
-
Yes
voltage on fan group 5 too high
mains input fan)
Yes
Yes
voltage on fan group 6 too low (=
smps fan)
-
Yes
voltage on fan group 6 too low (=
smps fan)
Yes
Yes
voltage on pump too low
-
Yes
voltage on pump too high
No
Yes
supply voltage for fans too low
No
Yes
supply voltage for fans too high
No
Yes
supply voltage for DMD cooling too
low
21. Troubleshooting
Action
check if air slot are free; clean air
filters
If problem persists, call a qualified
service engineer
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
check ambient conditions
check if air slot are free; clean air
filters
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
Hardware problem in Fan control
board, call a qualified service
engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents