Barco FLM R22+ User Manual page 220

Hide thumbs Also See for FLM R22+:
Table of Contents

Advertisement

21. Troubleshooting
Error
Description
code
7664
Blue block
temp high
7663
Blue block
temp open
7662
Blue block
temp short
7660
Engine air temp
high
7659
Engine air temp
open
7658
Engine air temp
short
7999
Fan speed
cathode too
low
7998
Fan speed
cathode high
7997
Fan speed
anode too low
7996
Fan speed
anode high
7995
Fan speed
engine too low
7994
Fan speed
engine high
7993
Fan speed cold
mirror too low
7992
Fan speed cold
mirror high
7991
Fan speed heat
ex. too low
7990
Fan speed heat
ex. high
7989
Fan speed
smps 1 too low
7987
Fan speed
smps 2 too low
7985
Red DMD temp
low
7984
Red DMD temp
high
7983
Green DMD
temp low
7982
Green DMD
temp high
7981
Blue DMD
temp low
216
Error
Warning
Caused by
Yes
Yes
High temperature on blue DMD
cooling block
Yes
Yes
Temperature sensor on blue DMD
cooling block not connected
Yes
Yes
Temperature sensor on blue DMD
cooling block shorted
Yes
Yes
High temperature on engine
Yes
Yes
Temperature sensor on engine not
connected
Yes
Yes
Temperature sensor on engine
shorted
Yes
Yes
fan is running too slow or not at all
-
Yes
Yes
Yes
fan is running too slow or not at all
-
Yes
Yes
Yes
fan is running too slow or not at all
-
Yes
Yes
Yes
fan is running too slow or not at all
Yes
Yes
fan is running too slow or not at all
-
Yes
Yes
Yes
fan is running too slow or not at all
Yes
Yes
fan is running too slow or not at all
No
Yes
low temperature on dmd
Yes
Yes
high temperature on dmd
No
Yes
low temperature on dmd
Yes
Yes
high temperature on dmd
No
Yes
low temperature on dmd
Action
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
turning on the lamp will heat up the
dmd
check if air slot are free; clean air
filters
If problem persists, call a qualified
service engineer
turning on the lamp will heat up the
dmd
check if air slot are free; clean air
filters
If problem persists, call a qualified
service engineer
turning on the lamp will heat up the
dmd