Barco FLM R22+ User Manual page 222

Hide thumbs Also See for FLM R22+:
Table of Contents

Advertisement

21. Troubleshooting
Error
Description
code
7954
VTEC voltage
high
7953
VMTR voltage
low
7952
VMTR voltage
high
7945
5V voltage low
7944
5V voltage high
7943
5V FIB voltage
low
7942
5V FIB voltage
high
7941
5V PMP
voltage low
7940
5V PMP
voltage high
7939
Prism
7938
Lamp not
inserted well
7937
Waterflow
7936
Tilt
7935
Engine not well
inserted
7934
FIB not
inserted well
7931
PFC HS high
temp
7929
SMPS HS high
temp
7928
Overtemp
7927
fan speed
mains input
too low
7926
fan speed
mains input
high
8000
Opening
shutter failed
8001
Closing shutter
failed
8002
Lamp
EEPROM
9000
Scaler unit
failed
9198
Scaler pixel
clock too high
218
Error
Warning
Caused by
No
Yes
supply voltage for DMD cooling too
high
No
Yes
supply voltage for motors too low
No
Yes
supply voltage for motors too high
No
Yes
supply voltage for electronics too
low
No
Yes
supply voltage for electronics too
high
No
Yes
supply voltage for engine
electronics too low
No
Yes
supply voltage for engine
electronics too high
No
Yes
supply voltage for drawer
electronics too low
No
Yes
supply voltage for drawer
electronics too high
No
Yes
projection lens to close to prism
Yes
No
lamp module not correctly inserted
Yes
No
bad or no water flow in cooling
circuit
No
Yes
tilt angle is out of specifications
Yes
No
engine is not correctly inserted
Yes
No
formatter interface board is not
correctly inserted
Yes
Yes
high temperature on smps
Yes
Yes
high temperature on smps
Yes
No
extreme overheating of dmd's or
lamp
Yes
Yes
fan is not running or is running too
slow
-
Yes
No
Yes
No
Yes
No
Yes
-
Yes
Initialization of the scaler failed
-
Yes
BW or refresh rate of input source
too high
Action
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
move lens away from prism (up
and/or right)
reinsert lamp module and screw
firmly
If problem persists, call a qualified
service engineer
Correct projection installation.
Change the tilting so that the
tilt angle becomes within the
specifications.
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
R59770179 FLM R22+ 15/03/2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents