21. Troubleshooting
Error
Description
code
2802
LPS start failed
2203
BOOST start
failed
2503
BOOST start
failed
2803
BOOST start
failed
2206
Lamp ignition
failed
2506
Lamp ignition
failed
2806
Lamp ignition
failed
2207
Lamp voltage
range
2507
Lamp voltage
range
2807
Lamp voltage
range
2208
Lamp power
range
2508
Lamp power
range
2808
Lamp power
range
4000
Incompatible
hardware
4199
FIB reset failed
5098
Flash full
5097
Flash
management
full
5096
Storing
unsuccessful
5095
Restoring
unsuccessful
6099
6098
7698
Light pipe temp
high
7697
Light pipe temp
open
7696
Light pipe temp
short
7695
Red front DMD
temp low
214
Error
Warning
Caused by
-
Yes
LPS (address 0x28)
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
Yes
No
Incompatible hardware used
-
Yes
no communication with FIB
-
Yes
Internal Backup device has reached
its maximum capacity
-
Yes
Internal Backup device has reached
its maximum capacity
-
Yes
Storing the custom settings into
internal backup device has failed
-
Yes
Restoring the custom settings from
internal backup device has failed
Yes
Yes
High temperature on light pipe entry
Yes
Yes
Temperature sensor on light pipe
not connected
Yes
Yes
Temperature sensor on light pipe
shorted
No
Yes
Low temperature on red DMD
Action
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualified service engineer
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualified service engineer
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualified service engineer
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Change to correct hardware
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD