11. Lamp menu
Image 11-10

11.5 CLO target

What must be done?
The light output target for the CLO is set in this menu item. This value will be forced on the projector provided the CLO mode has
been set On.
How to enter the value
1. Press MENU to activate the menus.
2. Use the ▲ or ▼ key to select Lamp and press ENTER.
3. Use the ▲ or ▼ key to select Power and press ENTER.
4. Use the ▲ or ▼ key to select CLO target lumens and press ENTER to activate the first digit.
5. Use ◄ or ►, the numeric keys on the remote, or the keypad to change the target value.
Image 11-13
11.6 Lamp Identification
About
The lamp identification menu gives an overview of the most important parameters of the used lamp.
These parameters are:
Serial number lamp
Article number of the used lamp
Run time since first start up of the lamp
Remaining run time for a safe operation of the lamp
Number of strikes since the first start up of the lamp
114
Image 11-11
Image 11-14
Image 11-12
Image 11-15
R59770179 FLM R22+ 15/03/2010