Basic Operating Procedures

1. Ensure that the printer power switch is set to "0" (off).
2. Connect the printer to the power supply using the cable [9B] provided.
3. Using the data cable supplied, connect the Centronics interface [9A] on the
4. Turn on the printer using the power switch (set to position "1"). The following
USER MANUAL

Connecting the printer

WARNING!
The printer operates using mains voltage! Touching electrically live parts
can cause exposure to hazardous electrical currents and may lead to
burns.
Make sure that the printer is switched off before connecting the power
cable.
Only operate the printer using the system voltage indicated on the
nameplate.
Only connect the printer to a grounded power socket fitted to authorised
standards.
The power cable should be run to the printer so that
– nobody will trip on it, and that
– the power plug can easily be pulled out if necessary.
printer to the host computer.
[9]
Sockets for the Centronics cable (A) and power cable (B) on the AP 7.t
sequence of messages is displayed:
System start...
System start...
Start user prog
AP 7.t
203 Dpi
V 2.34
AP 7.t
A
B
The boot loader is starting.
Valid firmware recognised, program is starting.
Printer type (here: AP 7.t with 203 dpi)
Version number of the printer firmware