4.2
System Programming
Description
Selection
Default
Programming
Conditions
Feature Reference
Room Monitor Assignment
Assigns which extensions can be monitored by another telephone.
• Jack number: 01 – 24,
• Disable / Enable
All jacks – Disable
1.
Enter 612.
Display: Room Monitor
2.
Press NEXT.
Display: Jack NO?
3.
Enter a jack number.
Pressing NEXT also can enter jack number 01.
Display example: #01:Disable
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another jack, press NEXT or PREV, or
SELECT and enter the desired jack number.
7.
Repeat steps 4 through 6.
8.
Press END.
• To assign all jacks to the same selection, press the
this case, the display will show: #
• The jacks which are assigned to "DISABLE" cannot accept feature
number "7351#" for the room monitor feature.
Section 3, Features
Room Monitor
(
= all jacks)
:Mixed.
System Programming
612
key in step 3. In
4-113