8-8 Troubleshooting
Virtual LCD indications when STATUS lamp is flashing in amber
On-screen message
HDD X Fault
E-Keying Error
Location Error
Cooling Error
AmbientTempAlm07
AmbientTempAlm00
BB +1.0v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.0vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
Description
An error was detected in hard
disk drive installed in Storage and
I/O Blade.
X: Indicates slot number
containing the failing hard disk
drive with 0-origin number.
In the Blade Enclosure,
combination of installation
locations of Storage and I/O
Blade, mezzanine card, and
switch module is not correct.
Thus, an unconformity of
interface signal was detected and
the CPU blade failed to power on.
In the Blade Enclosure, the
installation location of Storage
and I/O Blade is incorrect, or the
installation locations of the fan
and Storage and I/O Blade are
incorrect. Thus, the CPU blade
failed to power on.
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade failed
to power on due to insufficient
cooling power.
A high temperature warning was
detected in Storage and I/O
Blade.
A low temperature warning was
detected in Storage and I/O
Blade.
A voltage warning was detected
on Storage and I/O Blade.
XX=07: Upper limit warning
XX=00: Lower limit warning
Action
Contact your service representative.
Refer to the User's Guide of Blade
Enclosure for correct installation
locations.
If the same error persists, contact your
service representative.
Refer to the User's Guide of Blade
Enclosure to check if the Storage and I/O
Blade is installed in correct location.
Check the installation locations of the fan
and Storage and I/O Blade.
If the same error persists, contact your
service representative.
Check if fans in Blade Enclosure work
normally.
Refer to the User's Guide of the Blade
Enclosure to make sure that the
sufficient number of fans are installed in
correct locations.
Check if the fans and Storage and I/O
Blade are installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
Contact your service representative.

Advertisement