Panel Operation - Gemini GEM-P801 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P801:
Table of Contents

Advertisement

WI1089 GEM-P801 Installation Instructions
Keypad LEDs
ARMED LED DEFINITION
Armed
Instant Mode
Zone in Alarm
STATUS LED DEFINITION
Ready to be Armed
Zone faulted
TROUBLE LED DEFINITION
H
AC Failure
System Trouble(s)
FIRE LED DEFINITION
I
Fire Alarm
Fire Memory/*Fire Trbl
*See Note 1
AC LED DEFINITION
AC Present
AC Failure
ZONE LED DEFINITION
Faulted Zone
Bypassed Zone
Zone in Alarm
N
:
OTE
* If Fire Trouble on Fire LED [96-4] has been enabled, a steady
Fire LED will indicate Fire Trouble.
8

Panel Operation

Arming (System ON)
Before arming the system close all protected
ON
zones (unless programmed as Auto-Bypass
Rapid Flash
Reentry Zones).
Flashing
code, followed by the
provide a feedback beep for each key pressed.
If a valid Arm/Disarm code is entered, the
ON
keypad will beep 3 times. If an incorrect Arm/
OFF
Disarm code is entered, the keypad will sound a
1-second tone indicating an incorrect entry.
Flashing
Arming without Entry Delay (Instant
ON
Mode)
Enter the
The ARMED LED will flash rapidly to indicate
Flashing
the panel is in Instant Mode. If an Exit/Entry
ON
Zone is tripped while the panel is in Instant
Mode the panel will go into alarm immediately.
Arming/Disarming with a Keyfob
ON
The system can be armed by pressing the
OFF
key, and disarmed by pressing the
the Keyfob. Zones programmed as Exit/Entry
Follower Zones can be bypassed when the
ON
Slow Flash
or
N
Flashing
programmed for Interior [81-84].
programmed as Home/Away with Delay Zones
can be armed regardless of the state of the
Exit/Entry Zones when the
the Keyfob have been programmed for Full Set
[81-84]. To arm the system with all zones
Enter a 4-digit Arm/Disarm
key, the keypad will
D
key to eliminate the entry delay.
F
key on
L
keys on the Keyfob have been
Zones
or
keys on
M
N
protected press the
K
or
key for 1.5s to fully set the system
M
N
(The LED on the Keyfob indicate the Keyfob has
transmitted
the
signal).
Keyswitch Chirp [23-4] for an audible indication of
system arming and disarming.
Arming/Disarming with a Keyswitch
The system can be armed/disarmed by using a
momentary Keyswitch wired to Zone 6. Program
Keyfob/Keyswitch Chirp [23-4] for an audible
indication of system arming and disarming. To
convert keyswitch operation from Normally
Closed style to Normally Open, program [27-1]
Keyswitch Polarity.
N
:
OTE
Faulted Keyswitch or silent 24 hour zone normally do not
display at the keypad. If a silent 24 hour zone or Keyswitch
is faulted at the time of arming the faulted zone will display
only while the priority sound is ON.
Arming Instant with a Keyfob
The panel can be ARMED INSTANT when the
K
[A1] or [A2] keys on the Keyfob have been
programmed for
Instant [81-84]. To arm the
system with Instant protection press the [ON]
M
key, then press and hold the [A1] or [A2] key for
1.5s to arm the panel with INSTANT protection.
Disarming (System OFF)
After entering the premises through an Exit/Entry
Zone, the keypad will sound the Entry Delay
Tone. Enter a valid Arm/Disarm code, then press
J. If a valid Arm/Disarm code is entered, the
key. Press and hold the
Program
Keyfob/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents