Telephone Number 3 Programming; Report Codes; Enhanced Communicator Features - Gemini GEM-P801 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P801:
Table of Contents

Advertisement

WI1089 GEM-P801 Installation Instructions
each time a report is sent.
(2) Reserved
(3) Reserved
(4) Reserved
Telephone 3 Programming
[50] - [59]
Programming is the same as for Telco 1.
Program to split/double report to Telco 3.
Refer to sections [30] through [39].

Report Codes

[60]Zone Report Codes
Report Code for Zones 1 through 8.
4/2 format - The Zone Report Code is the 1st
digit of the report code sent, the second digit
is the zone number of the reporting zone.
For example, if zone 2 has a report code of 3,
the report code would be 32.
3/1 format - Sends only the report Code and
does not append it with the zone number.
[61]Point ID Report Codes
Point ID Report Codes are defaulted to
Burglary for zones 1 through 8. Optionally,
Point ID codes for zones 1 through 8 can be
programmed as follows:
[1] Fire
[7] Gas Alarm
[2] Panic
[8] Heat Alarm
[3] Burglary
[9] Reserved
[4] Holdup
[A] Auxiliary
[5] General Alarm
[B] 24 Hour
[6] Reserved
18
[62]Zone Codes
[62-1] Restore code - Zones 1 through 8.
The second digit of the restore code is the
zone number of the restored zone.
example, if the Zone Restore Code [62] is
programmed to E, the restore code for that
zone would be E4 (4/2 format).
[62-2] Trouble Code - Conditional Closing
Reports. Zones that are bypassed at the
time of arming send this code along with the
zone number of the bypassed zone(s). For
example a conditional closing by User 2,
with zones 2 and 3 bypassed would be as
follows:
1234
C2
F2
F3
[63]System Report Codes
Program a 2-digit report code for Keypad
Fire, Keypad AUX, Keypad Panic, Test
Timer, AC Fail, Low Battery, Trouble and
Fire.
[64]System Restore Code
The code sent when a system condition
restores.
The second digit of the 2-digit
restore code is the second digit of the
System Report Code [63]. For example, if a
Low Battery System Report Code is F8 the
Battery Restore would be E8 (4/2 format).
[65]Opening and Closing Codes
Program Opening and Closing Codes for
Users 1 through 8. The second digit of the
report code is the number of the user that
armed or disarmed the system. For example,
For
if the Closing Code [65] is programmed
with a C, the closing code for User 2 would
be C2 (4/2 format).
[66]Ambush Report Code
Program a 2-digit report code for Ambush.
To send an ambush report, program a User
Code for User 8, Program report User 8 as
Ambush [20-4] and Select reporting for Telco
1 [36-2] and/or Telco 3 [56-2].
Enhanced Communicator
Features
[67]Telephone Number 1
(1) Opening After Alarm (Cancel Code) -
When enabled, all users that are not selected
to report on Opening/Closing [39] will report
an Opening only
alarm has occurred.
(2) Conditional Closing Telephone 1 -
When enabled, all users that are not selected
to report an Opening/Closing ([39], [59]) will
report a Closing only when zones have been
bypassed. The Zone Trouble Code [62-2] is
used to report zones that have been
bypassed at the time of the closing report.
when opening after an