WI1089 GEM-P801 Installation Instructions
System Troubles
Keypad Beeps or
Zone LED
SYSTEM
ON
j
Flashes
1 Beep
1
2
3
4
2 Beeps
1
2
3
4
3 Beeps
1-6
4 Beeps
1-6
5 Beeps
1-4
6 Beeps
1-4
7 Beeps
1-6
24
System Trouble
Condition
AC Power Failure
This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source.
Low Battery
If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If the
trouble does not go away in 24 hours, replace the battery.
Communication Failure /
The system was not able to report to central station. Check panel programming and telephone line wiring. The trouble will clear after
it has been acknowledged by viewing the system trouble as long as the telephone line has passed a line cut test (tested automatically
PCPreset Fail / Line Fail
by the panel).
Download ID number, Callback Number or PCPreset Setup.
Telephone Line Cut
The telephone line has failed. If telephone service has been temporarily interrupted, the trouble will clear when restored and
acknowledged by viewing the system trouble.
Bell/Siren line Cut
There is a problem with the Bell or Siren wiring. EOL2.2K resistor must be installed.
2-wire Fire Trouble
There is a problem with the wiring of the Fire Zone.
Rcvr Fail-to-Respond/Rcvr
The receiver is not responding to the panel. The red LED on the receiver should be flashing, refer to WI850. The cover is off the
receiver causing a tamper signal to be transmitted.
Tamper
Receiver Jam
A signal is blocking the normal reception of transmissions from the wireless devices. Ensure that the green LED on the receiver is not
on continuously, refer to receiver manual WI850.
Wireless
The battery in the wireless transmitter is low and should be replaced. This transmitter is on the zone corresponding to the number of
the zone light flashing. The replacement battery for the GEM Trans2 door/window transmitter and the GEM PIR wireless motion
Transmitter Low Battery
detector is the Duracell DL123A. (2 required for the GEM-PIR) WARNING: Replace batteries only with the same type as specified
above. Use of another battery may present a risk of fire or explosion. Do not recharge or disassemble battery or dispose of in fire.
Wireless
The panel has not received a supervisory signal from the transmitter within the time programmed. Check Wireless Supervisory Timer
[16] Programming. Check the placement of the transmitter and receiver, refer to WI850.
Transmitter
Supervisory Failure
Wireless Smoke Detector
The battery in the wireless smoke detector is low and should be replaced. This wireless smoke detector should be marked with a
number corresponding to the number of the zone light flashing. The replacement batteries required are *Duracell 9 Volt Alkaline (2).
Low Battery
Wireless Smoke Detector
The panel has not received a supervisory signal from the wireless smoke detector within the programmed time. Check Wireless
Smoke Supervisory Timer [17] Programming. Check the placement of the wireless smoke detector and receiver, refer to WI850.
Supervisory
Zone Trouble
The panel has one or more of the following 2 possible troubles: Transmitter Tamper or Dual Tech Self Test Fail.
Cause/Action
The Panel did not successfully connect and download/upload with the computer running PCPreset - check Auto