Chapter 5
4
Auto-size on Power-up: When enabled, the printer automatically sizes
the label to determine the appropriate format header values on power-
up. The printer will then use these values on all subsequent label
formats. Refer to the ^D39 command for additional information.
5,6,7,8
Code Page Selection: Positions 5 through 8 are used to select from
the available code pages stored within the printer.
See Chapter 9 for more details
5.2.2.5
Software Switch #5
^A
^D
COMMAND
XX
25
Change SW5: Software Switch #5.
^AB12345678 (each bit is represented by a numeric position number)
Position:
1
Single Button Press Clear: If enabled, error conditions are cleared
with a single press of the print button after reloading the printer with
more media. If this function is disabled, pressing the print button clears
the error condition, prints the pending job, and reenters the previous
halting error state. The button must be pressed and held during printing
in order to exit the error routine. This is used to reprint the pending job
until the print realigns before continuing.
2
>BUTTON PRESED< Status Enable: When enabled, pressing the
button will cause the printer to report the >BUTTON PRESSED< or
0xC0 depending on the printer's ^D21 response mode configuration.
This is typically used on systems that preload a batch of jobs to the
printer but wait on the >BUTTON PRESSED< message before sending
the print command.
224/424 Operator's Manual - 880027-1000
1 = Enable
0 = Disable
0000 = Not Decoded (Default)
0001 = Danish
0010 = 860
0011 = Spanish
0100 = 850
0101 = German
0110 = 865
0111 = Swiss
1 = Enable (Single Button Error Clear)
0 = Disable (Reprint and Align)
1 = Enable >BUTTON PRESSED<
0 = Disable
Printer Commands
1000 = 852
1001 = French
1010 = 863
1011 = Swedish
1100 = 437
1101 = Italian
1110 = English - UK
1111 = English – US