Parameter Edit Displays
ON/OFF Parameters
Parameters that are either ON or OFF are edited via this
type of display (e.g., Mute Parameter Edit display in "Mute
Switching" on page 42).
1.
Rotate the dial clockwise to select ON, or
counterclockwise to select OFF.
2.
Press enter to confirm the selection and close
the window.
Parameter Edit displays will also appear when the
[SCENE], [MUTE], [MONITOR] or other button is
pressed.
These allow scene changes, level adjustment, and other
settings to be edited as required.
Editing User Defined Parameters
1.
If the Main display is not showing, press the
[HOME] button to recall it.
2.
Press the [HOME] button until the page
containing the parameter to be edited appears.
3.
E ] [
Use the [
parameter to be edited.
4.
Press the [ENTER] button.
The Parameter Edit display for the selected user-defined
parameter will appear.
NOT E
User-defined parameters can be of all three types: numeric, list,
and ON/OFF.
NOT E
When editing from an ICP1 control panel, the [F1] ~ [F6]
buttons are used for parameter selection.
5.
Edit the user-defined parameter as required.
Refer to "Parameter Edit Displays" on page 40 for editing
procedures.
NOT E
Any changed user-defined parameter values will be lost if the
power is turned off or if scenes are changed. To preserve the
changed values, store the scene data.
42
DME64N/24N Owner's Manual
F ] buttons select the
] [
] [

Mute Switching

Turns the DME64N/24N output mute function ON or
OFF.
1.
Press the [MUTE] button.
The Mute Parameter Edit display will appear.
2.
Select Mute ON or OFF.
The mute function is turned on or off as described in
"ON/OFF Parameters" on page 42.
N OTE
To access this function from the ICP1 control panel, hold the
[F6] button for longer than 2 seconds.
N OTE
PHONES jack output is not muted.

Output Level Control

Adjust the output level of the DME64N/24N.
N OTE
Output level settings apply individually to each DME64N/24N
unit. There is no overall zone setting.
This function cannot be accessed from the ICP1 control panel.
1.
Press the [LEVEL] button.
The "Output Level" Parameter Edit display will appear.
2.
Adjust the numeric output level parameter as
required.
The Output Level parameter is adjusted as described in
"Numeric Parameters" on page 40. The graphic fader
provides a visual indication of the current output level
setting.