Yamaha DME64N Owner's Manual page 62

Digital mixing engine
Hide thumbs Also See for DME64N:
Table of Contents

Advertisement

Error Messages
Message
Saving Setup Info
Scene Recalling
Scene Storing
SLOT1 Sync Err
SLOT2 Sync Err
SLOT3 Sync Err
SLOT4 Sync Err
WCLK Unlocked
Zone Sync Err
62
DME64N/24N Owner's Manual
Meaning
Info set up via the Utility display (other than head
amplifier info) is being saved.
(Do not turn power off.)
Scene recall in progress.
Scene store in progress.
(Do not turn power off.)
The DME64N/24N clock is not synchronized with the
clock of the card installed in I/O slot 1.
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 2.
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 3.
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.
A usable word clock signal is not being received or
cannot be detected.
The DME64N/24N contains data of another zone or no
data.
Action
None required.
None required.
None required.
Make sure that the DME64N/24N and the card installed
in I/O slot 1 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 2 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 3 are set to use the same word clock.
Make sure that the DME64N and the card installed in I/O
slot 4 are set to use the same word clock.
Recheck all word clock connections and internal
parameters.
Send appropriate data from a computer running the DME
Designer application,