Options
2.
Connect the adaptor box to a network hub or the DME64N/24N.
Use a "straight" cable for connection to a hub, or a "cross" cable for direct connection to the DME64N/24N.
N OT E
• Use a 100Base-TX/10Base-T switching hub.
• When using category 5 UTP (Unshielded Twisted Pair) cable, the total length of the cables connecting the control panel unit
to the hub or DME64N/24N can be up to 100 meters. Due to differences in cable and switching hub performance, however,
proper operation at the maximum length cannot be guaranteed in some cases. The maximum usable cable length will also be
reduced if joint connectors, cross cable converters, or other extension adaptors are used.
• Use STP (Shielded Twisted Pair) cable to prevent electromagnetic interference.
3.
Connect the PA-300 AC adaptor to the adaptor box.
4.
Plug the AC adaptor into an appropriate AC mains outlet.
1.
NO T E
• Terminal box not included. Use a standard (US-type) wall box: 3-gang with a depth of 44 millimeters or more.
• The screw heads should extend from the frame plate by no more than 3 millimeters.
2.
NO T E
Tighten the screws used to attach the control panel to the frame plate with a torque of less than 1.5 Nm.
58
DME64N/24N Owner's Manual
Control panel unit
2
To network hub or
DME64N/24N.
MAD E IN
JAPA N
ICP1 adaptor box
Frame Plate and Control Panel Installation
Screw the frame plate to the terminal box.
Screw the control panel to the frame plate.
1
D C IN
ICP1 ADA
PTO R BOX
ICP 1
DC IN
3
AC adaptor (PA-300)
1
2
Frame plate for ICP1
Control panel unit
Cord hook
To AC power outlet