3 Functions
3.1.2
Interconnecting signals (BICO technology)
A state-of-the-art drive unit must be able to interconnect internal and external
signals (setpoint / actual values and control / status signal). This interconnection
functionality must have a high degree of flexibility in order to be able to adapt the
drive to new applications. Further, a high degree of usability is required, which also
fulfills standard applications. This is the reason that within the MICROMASTER
series of drive units, BICO technology (
using parameters P0700 / P1000 (
P0700/P1000) have been introduced to be able to fulfill both of these requirements.
3.1.2.1
Selecting the command source P0700 / selecting the setpoint source
P1000
The following parameters can be used to quickly interconnect setpoints and control
signals:
P0700
P1000
These parameters are used to define via which interface the drive inverter receives
the setpoint or the power-on/power-off command. The interfaces, listed in Table
3-2 can be selected for the command source P0700.
Table 3-2
Parameter values
0
1
2
4
5
6
The following internal or external sources / interfaces can be selected for the
frequency setpoint source P1000. In addition to the main setpoint (1
supplementary setpoint (2
44
"Selection of command source"
"Selection of setpoint source"
Parameter P0700
Significance / command source
Factory default
BOP (operator panel, refer to Section 3.2.1)
Terminal strip
USS on BOP link
USS on COM link
CB on COM link
nd
position) can be selected (refer to Table 3-3).
flexibility) and fast parameterization
usability) or P0719 (
MICROMASTER 420
Issue 07/04
combination
st
position), a
Operating Instructions
6SE6400-5AA00-0BP0