Table 3-8 Example 1La7060-4Ab10 - Siemens MICROMASTER 420 Operating Instructions Manual

0.12 kw - 11 kw
Hide thumbs Also See for MICROMASTER 420:
Table of Contents

Advertisement

3 Functions
Table 3-8
P0304
Rated motor voltage
P0305
Rated motor current
P0307
Rated motor power
P0308
Cos
P0310
Rated motor frequency
P0311
Rated motor speed
P0314
Motor pole pairs
Contrary to the BOP, AOP operator panels or commissioning tool program
DriveMonitor, the STARTER commissioning (start-up) program offers a mask-
orientated quick commissioning, which is especially advantageous for users who
are using MICROMASTER for the first time. On the other hand, BOP, AOP and
DriveMonitor offer, in conjunction with the drive inverter, parameter-orientated
quick commissioning where the user is navigated through the menu tree mentioned
above.
NOTE
The MICROMASTER series of drive units is not available for 3-ph. 690 V AC.
68
Example 1LA7060-4AB10
configuration
Delta circuit
87 Hz
characteristic
230 V
400 V
0.73 A
0.73 A
120 W
207 W
0.75
0.75
50 Hz
87 Hz
1350 RPM
2460 RPM
2
2
MICROMASTER 420
Issue 07/04
Star circuit
configuration
400 V
0.42 A
120 W
0.75
50 Hz
1350 RPM
2
Operating Instructions