Siemens MICROMASTER 420 Operating Instructions Manual page 77

0.12 kw - 11 kw
Hide thumbs Also See for MICROMASTER 420:
Table of Contents

Advertisement

Issue 07/04
Fixed frequency code –
P1016 =...
Bit 0
Defines the selection method for fixed
frequencies.
Fixed frequency code –
P1017 =...
Bit 1
Fixed frequency code –
P1018 =...
Bit 2
3.5.5.10
JOG
JOG frequency right
P1058 =...
Frequency in Hz when the motor is being
jogged in the clockwise direction of rotation.
JOG frequency left
P1059 =...
Frequency in Hz when the motor is being
jogged in the counter-clockwise direction of
rotation.
JOG ramp-up time
P1060 =...
Ramp-up time in s from 0 to the maximum
frequency (P1082). The JOG ramp-up is
limited by P1058 or P1059.
JOG ramp-down time
P1061 =...
Ramp-down time in s from the maximum
frequency (P1082) to 0.
3.5.5.11
Ramp-function generator (HLG)
Skip frequency 1 (entered in Hz)
P1091 =...
Defines skip frequency 1 which avoids
effects of mechanical resonance and
suppresses frequencies within +/- P1101
(skip frequency bandwidth).
Skip frequency 2
P1091 =...
Skip frequency 3
P1091 =...
Skip frequency 4
P1091 =...
Skip frequency bandwidth
P1101 =...
(entered in Hz)
Ramp-up time
P1120 =...
(enters the accelerating time in s)
Ramp-down time
P1121 =...
(enters the deceleration time in s)
MICROMASTER 420
Operating Instructions
6SE6400-5AA00-0BP0
1
1
Direct selection
2
Direct selection + ON command
3
Binary coded selection + ON command
NOTE
1
For settings 2 and 3, all parameters P1016 to
P1019 must be set to the selected value so that
the drive inverter accepts the ON command.
1
5.00 Hz
JOG
5.00 Hz
f
P1082
(f
)
max
P1058
10.00 s
10.00 s
P1060
0.00 Hz
f
out
0.00 Hz
0.00 Hz
0.00 Hz
P1091
Skip frequency
2.00 Hz
10.00 s
f
P1082
(f
)
max
f
1
10.00 s
P1120
3 Functions
t
P1061
P1101
Skip frequency
bandwidth
f
in
t
P1121
77