Tape Alert Flags - IBM System x3650 M3 4255 Service Manual

Problem determination and service guide
Hide thumbs Also See for System x3650 M3 4255:
Table of Contents

Advertisement

Table 9. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, Types 4255, 7945, and 7949 server," on page 157 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
405-907-xxx
Broadcom
Ethernet
Device
405-908-xxx
Broadcom
Ethernet
Device

Tape alert flags

If a tape drive is installed in the server, go to http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?lndocid=MIGR-5079217&brandind=5000008 for the Tape
Storage Products Problem Determination and Service Guide. This document
describes troubleshooting and problem determination information for your tape
drive.
Tape alert flags are numbered 1 through 64 and indicate specific media-changer
error conditions. Each tape alert is returned as an individual log parameter, and its
108
IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide
Test
State
Description
Test Loop
Failed
back at
MAC-Layer
Test LEDs
Failed
Action
1. Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 253.
2. Run the test again.
3. Replace the component that is causing the error.
If the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.
4. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 253.
2. Run the test again.
3. Replace the component that is causing the error.
If the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.
4. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3650 m3 7945System x3650 m3 7949

Table of Contents