IBM System x3650 M3 4255 Service Manual page 114

Problem determination and service guide
Hide thumbs Also See for System x3650 M3 4255:
Table of Contents

Advertisement

Table 9. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, Types 4255, 7945, and 7949 server," on page 157 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
201-805-xxx
Memory
201-806-xxx
Memory
201-807-xxx
Memory
96
IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide
Test
State
Description
Memory Test
Aborted
Test canceled:
the memory
controller
display/alter
write operation
was not
completed.
Memory Test
Aborted
Test canceled:
the memory
controller fast
scrub operation
was not
completed.
Memory Test
Aborted
Test canceled:
the memory
controller buffer
free request
failed.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 253.
4. Run the test again.
5. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 253.
4. Run the test again.
5. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 253.
4. Run the test again.
5. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.