operating systems to run on a host system at the same time. The USB flash device
is required to activate the hypervisor functions.
To start using the embedded hypervisor functions, you must add the USB flash
device to the boot order in the Setup utility.
To add the USB flash device to the boot order, complete the following steps:
1. Turn on the server.
2. When the prompt <F1> Setup is displayed, press F1.
3. From the Setup utility main menu, select Boot Manager.
4. Select Add Boot Option; then, select Embedded Hypervisor. Press Enter, and
5. Select Change Boot Order and then select Commit Changes; then, press
6. Select Save Settings and then select Exit Setup.
If the embedded hypervisor flash device image becomes corrupt, you can use the
VMware Recovery CD to recover the flash device image. To recover the flash
device image, complete the following steps:
1. Turn on the server.
2. Insert the VMware Recovery CD into the CD or DVD drive.
3. Follow the instructions on the screen.
For additional information and instructions, see the ESXi Embedded and vCenter
Server Setup Guide at http://www.vmware.com/pdf/vsphere4/r40_u1/
vsp_40_u1_esxi_e_vc_setup_guide.pdf.

Enabling the Broadcom Gigabit Ethernet Utility program

The Broadcom Gigabit Ethernet Utility program is part of the server firmware. You
can use it to configure the network as a startable device, and you can customize
where the network startup option appears in the startup sequence. Enable and
disable the Broadcom Gigabit Ethernet Utility program from the Setup utility.

Configuring the Gigabit Ethernet controller

The Ethernet controllers are integrated on the system board. They provide an
interface for connecting to a 10 Mbps, 100 Mbps, or 1 Gbps network and provide
Note: Approximately 20 to 40 seconds after the server is connected to power,
the power-control button becomes active.
then select Esc.
Enter.
Note: Approximately 20 to 40 seconds after the server is connected to power,
the power-control button becomes active.