IBM System x3650 M3 4255 Service Manual page 142

Problem determination and service guide
Hide thumbs Also See for System x3650 M3 4255:
Table of Contents

Advertisement

Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, Types 4255, 7945, and 7949 server," on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Sensor Sys Board Fault has
transitioned to critical from a less
severe state.
The Power Supply (Power Supply:
n) has Failed.
(n = power supply number)
Sensor PS n Fan Fault has
transitioned to critical from a less
severe state.
(n = power supply number)
124
IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide
Error
A sensor has changed to Critical
state from a less severe state.
Error
Power supply nhas failed.
(n = power supply number)
Error
A sensor has changed to Critical
state from a less severe state.
1. Check the system-event log.
2. Check for an error LED on
the system board.
3. Replace any failing device.
4. Check for a UEFI firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5. (Trained service technician
only) Replace the system
board.
1. If the power-on LED is lit,
complete the following steps:
a. Reduce the server to the
minimum configuration
(see "Power-supply LEDs"
on page 69).
b. Reinstall the components
one at a time, restarting
the server each time.
c. If the error recurs, replace
the component that you
just reinstalled.
2. Reseat power supply n.
3. Replace power supply n.
(n = power supply number)
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Replace power supply n.
(n = power supply number)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3650 m3 7945System x3650 m3 7949

Table of Contents