Program Change

status
2nd byte
CnH
ppH
pp=Program number:
00H–7FH (prog.1–prog.128)
Channel Aftertouch
status
2nd byte
DnH
vvH
* The effect will apply according to the Aftertouch Control setting.
Pitch Bend Change
status
2nd byte
EnH
llH
mm,ll=Pitch Bend value:00 00H–40 00H–7F 7FH (-8192–0–+8191)
* The effect will apply according to the Pitch Bend Control setting.
Channel Mode messages
All Sound Off (Controller number 120)
status
2nd byte
BnH
78H
* When this message is received, all notes currently sounding on the corresponding
channel will be turned off.
Reset All Controllers (Controller number 121)
status
2nd byte
BnH
79H
* When this message is received, the following controllers will be set to their reset values.
Controller
Reset value
Pitch Bend Change
±0 (center)
Polyphonic Key Pressure
0 (off)
Channel Pressure
0 (off)
Modulation
0 (off)
Expression
127 (maximum)
Hold 1
0 (off)
Sostenuto
0 (off)
Soft
0 (off)
Hold 2
0 (off)
RPN
Unset. Previously set data will not change.
All Note Off (Controller number 123)
status
2nd byte
BnH
7BH
* When All Note Off is received, all currently sounding notes of the corresponding
channel will be turned off. However if Hold 1 or Sostenuto are on, the sound will be held
until these are turned off.
Omni Off (Controller number 124)
status
2nd byte
BnH
7CH
* The same processing as when All Note Off is received will be done.
Omni On (Controller number 125)
status
2nd byte
BnH
7DH
* The same processing as when All Note Off is received will be done. The instrument will
not be set to OMNI ON.
Mono (Controller number 126)
status
2nd byte
BnH
7EH
mm=Mono number: 00H–10H (0–16)
* The same processing as when All Note Off is received will be done, and the Solo Switch
parameter will be set to ON.
3rd byte
mmH
3rd byte
00H
3rd byte
00H
3rd byte
00H
3rd byte
00H
3rd byte
00H
3rd byte
mmH
MIDI Implementation
Poly (Controller number 127)
status
2nd byte
BnH
7FH
* The same processing as when All Note Off is received will be done, and the Solo Switch
parameter will be set to OFF.

System Realtime messages

Timing Clock

status
F8H
* Settings can be made to synchronize or the LFO rate or the effect rate.
Active Sensing
status
FEH
* When an Active Sensing message is received, the unit will begin monitoring the interval
at which MIDI messages are received. During monitoring, if more than 420 ms passes
without a message being received, the same processing will be done as when All Sound
Off, All Note Off, and Reset All Controllers messages are received. Then monitoring will
be halted.

System Exclusive messages

status
data byte
F0H
iiH, ddH, ......, eeH
F0H:
System Exclusive message status
ii = ID number:
This is the ID number (manufacturer ID) that specifies the
manufacturer whose exclusive message this is. Roland's manufacturer
ID is 41H.ID numbers 7EH and 7FH are defined in an expansion of the
MIDI standard as Universal Non-realtime messages (7EH) and
Universal Realtime Messages (7FH).
dd,..., ee = data:
00H–7FH (0–127)
F7H:
EOX (End Of Exclusive) This is the last status of system exclusive
message.
Universal Non-realtime System Exclusive Messages
IdentityIdentity Request Message
Status
Data byte
F0H
7EH, dev, 06H, 01H F7H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (universal non-realtime message)
dev
Device ID (dev:10H(17)-1FH(32))
06H
Sub ID#1 (General Information)
01H
Sub ID#2 (Identity Request)
F7H
EOX (End Of Exclusive)
* The "dev" is own device number or 7FH (Broadcast)
* When Identity Request is received, Identity Reply message will be transmitted.
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is transmitted
as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted.
The model ID of the exclusive messages used by this instrument is 00 0BH.
status
data byte
F0H
41H, dev, 00H, 0BH, 11H, aaH, bbH,
ccH, ddH, ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H–1FH)
00H
model ID (D2)
0BH
model ID (D2)
3rd byte
00H
status
F7H
Status
status
F7H
99