1–Operations and Administration
Configuration and Monitoring Features
This trap indicates that there was a fail over from one switch in the chassis
to the other.
Slot Group
icsChassisTrapModuleNotResponding
This trap indicates that a module is not responding to HEARTBEAT poll
requests, that are issued by the internal chassis management service.
icsChassisTrapModuleInserted
This trap indicates that a module was inserted into the chassis.
IcsChassisTrapModuleRemoved
This trap indicates that a module was removed from the chassis.
icsChassisTrapModuleFailed
This trap indicates that a module has failed and is not operational.
icsChassisTrapModuleSelfTestFailure
This trap indicates that the module failed one or more of its self-test.
icsChassisTrapModuleEEPROMReadFailure
This trap indicates that an error condition was encountered when reading
the EEPROM of the module.
icsChassisTrapModuleFPGAReadFailure
This trap indicates that an error condition was encountered when reading
the Field-Programmable Gate Array (FPGA) of the module.
icsChassisTrapModuleBulkPowerFailure
This trap indicates that the bulk power used by a module has failed within
the chassis.
icsChassisTrapModuleReboot
This trap indicates that the module is in the process of rebooting.
Power Group
icsChassisTrapPowerSupplyNotResponding
This trap indicates that a power supply is not responding to HEARTBEAT
poll requests, that are issued by the internal chassis management service.
icsChassisTrapPowerSupplyInserted
This trap indicates that a power supply was inserted into the chassis.
icsChassisTrapPowerSupplyRemoved
This trap indicates that a power supply was removed from the chassis.