Electrolux ICON appliances Design Manual page 88

Table of Contents

Advertisement

I/P Vent Hood
RH42PC60GS
planning
information
For 42" model:
RH42PC60GS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Duct-Free Kit
PN # RHDFP60GS
88
cooking
Island Vent Hoods
PRE-INSTALLATION CALCULATIONS
K = Kitchen height
C = Counter height
S H
P = Preferred height
of hood bottom
above counter
A
(24"- 30"
allowed, NOT
more than 36"
K
P
recommended)
A = Canopy height
H = Hood height for
Counter Height
installation
36" standard
H = K-C-P
C
S = Chimney
structure height
for installation
S = H-A
2
/
"
11
16
Top
Wiring box
Controls
Installation Specifications
Product Weight – 87 Lbs.
Island / Peninsula Ceiling-Mount Installation
Ventilation system is preset to exhaust air outside. If
outside ducting is not possible, optional Duct-Free Kit
(PN # RHDFP60GS) is available to convert ventilation
to allow air to recirculate inside. (Refer to Ducted
Option Specifications for outside ventilation.)
Sones Rating – 9.9
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.516 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 4.16 Amps
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
Minimum installation height allowed from bottom of
hood to cooking surface is 24" - 30" for electric and 30"
for gas. (NOT more than 36" recommended.)
To prepare mounting surface, adequate structure and
support must be provided, capable of supporting 150 lbs.
12
/
"
1
8
41
7
/
"
8
Air outlet -
7
/
" diam.
7
8
Ducted Option Specifications
For outside ventilation.
Exhaust Duct Required – 8" round
For most efficient airflow exhaust, use a straight run or as
few elbows as possible.
Use metallic flex ducting only to connect rigid duct directly
to transitions (if allowed by code).
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
Cold weather installations should have additional backdraft
damper installed.
Refer to installation instructions on web for detailed exhaust
duct preparation and converting vent blower system for
recirculating inside.
Pre-Installation Calculations
Select hood preference height (P) that is comfortable
for user (24" - 30" minimum allowed, NOT more than
36" recommended).
Calculate hood height (H) for installation (H = K-C-P).
Confirm that (H) is within minimum to maximum range for
hood. If not, adjust installation.
Calculate chimney structure height (S). Use formulas,
check dimensions of hood. Save calculation for use later
in installation.
13
/
"
3
16
min.
max.
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
28"
installation.
( min.
height
with one
cover)
25
/
"
3
16
35"
57"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents