Ice Makers
E15IM60GPS/E15IM60GSS (Combination)
Under-Counter Ice Makers
Installation Specifications
Product Weight – 100 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.48 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Run Amps @ 120 Volts = 4.0 Amps
Harvest Amps @ 120 Volts = 5.5 Amps
Electrical cable supplied.
Water supply and electrical power source required.
Always consult local and national electric & plumbing
codes.
Unit is designed for either freestanding or built-in,
under-counter installation.
Built-in, under-counter installation does not require
additional airspace for top, sides or rear of unit.
Allow 1-1/2" minimum clearance behind unit for
electrical, water supply and drain connections.
Front grille MUST remain unobstructed for proper
ventilation.
Can be installed using gravity drain or optional Drain
Pump Kit (PN # EIMP60).
Drain lines must have 5/8" inside diameter, 1" drop per
48" (1/4" per foot) of run and must not create traps.
Floor drain must be large enough to accommodate
drainage from all drains.
Recommended water pressure between 30 and 120
pounds per square inch (psi).
Unit MUST be level for proper operation, and positioned
on flat surface, capable of supporting entire weight
when fully loaded.
Leveling legs supplied to adjust height and level unit.
Can be installed outdoors, out of direct sunlight.
Do NOT install behind closed doors.
Do not position unit near any heat source or in direct
sunlight to ensure optimum performance. Surrounding
air temperature must be at least 50° F but must not
exceed 110° F.
Unit requires zero clearance when installing flush with
cabinet or wall.
When installing against cabinet or wall that extends
beyond front edge of unit, 2-7/8" minimum handle
clearance required to allow for 90° door swing, providing
sufficient interior access. (Door is field reversible for
right- or left-hand opening.)
e l e c t ro l u x i c o n . c o m
planning
information
For models:
E15IM60GPS
E15IM60GSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Installation drawing shown
with professional series model.
Optional
Accessories
Drain Pump Kit
PN # EIMP60
Cleaning Kit
PN # EIM41978