E36WV100FS
planning
information
For 36" model:
E36WV100FS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
31-7/8" Flue
Extension
PN # EXWV100S
82
cooking
Wall-Mount Vent Hoods
Air outlet - 7
/
" diam.
7
8
6
/
"
3
16
Top
Installation Specifications
•
Product Weight – 64 Lbs.
•
Wall-Mount Installation
•
Sones Rating – 10.0
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.68 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 6.26 Amps
•
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
10
3
/
"
8
Wiring box
36"
•
Vent unit outside of building only.
•
Exhaust Duct Required – 8" round
•
For most efficient airflow exhaust, use a straight run
or as few elbows as possible.
•
Use metallic flex ducting only to connect rigid duct directly
to transitions (if allowed by code).
•
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
•
Cold weather installations should have additional backdraft
damper installed.
•
For most efficient operation, position hood low to cooktop.
Recommended installation is 30" - 36" above countertop.
12
/
"
3
4
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
2
/
"
1
16
24"
5" min.
20
/
" max.
1
2
33"min.
48
/
"max.
5
8
17
/
"
1
8
11"