E36WV100FS
planning
information
For 36" model:
E36WV100FS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
31-7/8" Flue
Extension
PN # EXWV100S
82
cooking
Wall-Mount Vent Hoods
Air outlet - 7
/
" diam.
7
8
6
/
"
3
16
Top
Installation Specifications
Product Weight – 64 Lbs.
Wall-Mount Installation
Sones Rating – 10.0
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.68 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 6.26 Amps
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
10
3
/
"
8
Wiring box
36"
Vent unit outside of building only.
Exhaust Duct Required – 8" round
For most efficient airflow exhaust, use a straight run
or as few elbows as possible.
Use metallic flex ducting only to connect rigid duct directly
to transitions (if allowed by code).
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
Cold weather installations should have additional backdraft
damper installed.
For most efficient operation, position hood low to cooktop.
Recommended installation is 30" - 36" above countertop.
12
/
"
3
4
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
2
/
"
1
16
24"
5" min.
20
/
" max.
1
2
33"min.
48
/
"max.
5
8
17
/
"
1
8
11"