Countertop Preparation
planning
information
For models:
Cooktop
E30EC65ESS
E30EC70FSS
E30GC64ESS
E30GC70FSS
E30IC80ISS
E36EC65ESS
E36EC70FSS
E36GC65ESS
E36GC70FSS
E36IC80ISS
Downdraft Vent
E30DD75ESS
E36DD75ESS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
160
project planning
Drop-In Cooktop / Downdraft Vent Countertop Preparation
Countertop Preparation for 30" & 36" Drop-In Cooktop/ Downdraft Vent Installation
Vertical noncombustible surface - rear wall
Top
23
/
"
1
4
min.
C
Flush with
back side of
25"
cabinet front
E30DD75ESS /30" Cooktop Cutout Dimensions
30" Cooktops
A
B
E30EC65ESS
30"
27
E30EC70FSS
30"
27
E30GC64ESS
27
/
"
27
1
2
E30GC70FSS
28
/
"
27
1
2
E30IC80ISS
29
/
"
27
3
4
25" (standard countertop) *
Countertop
backsplash
3
/
" max. backsplash thickness
4
/
"min. flat ledge
1
4
2
/
"
13
16
Downdraft
2
/
"
1
chimney top
8
Studwall
3"
/
"
9
32
1
/
"
15
16
Vent unit
2
/
"
13
16
Stiffener
Vertical noncombustible surface - rear wall
Installation Specifications
Cooktop / Downdraft Vent Countertop
Preparation Specifications
For detailed Cooktop installation, refer to model-specific
Planning Information page and installation guide on web.
Plan installation so that all required minimum clearances
between cooktop, overhead cabinets and adjacent
vertical walls are provided.
Position cooktop / vent cutout so all required minimum
clearances are met.
Minimum flat countertop area must meet or exceed
combined overall width and depth as shown. Standard
25" countertop depth may NOT be adequate for some
cooktop / vent installations, especially with backsplash.
Separate circuits required for cooktop and vent. (Refer
to product-specific electrical specifications.)
Always consult local and national electric and gas codes.
Check local building codes for installation requirements,
as they may vary per locale.
Downdraft Vent Specifications
For detailed Downdraft Vent installations, refer to
model-specific Planning Information page and installation
guide on web.
Voltage Rating – 120V / 60 Hz / 15 Amps
B
D*
E**
A
C
D
E
/
"
20
/
"
23
/
" 24
/
"
3
3
3
3
4
8
16
16
/
"
20
/
"
23
/
" 24
/
"
3
1
1
1
4
4
16
16
/
"
19
/
" 22
/
" 23
/
"
3
7
11
11
4
8
16
16
/
"
19
/
"
22
/
" 23
/
"
3
3
9
9
4
4
16
16
/
"
20
/
"
23
/
" 24
/
"
3
1
5
5
4
2
16
16
Countertop
raised lip
Cooktop
Back side of
cabinet front
23
/
" min.
1
4
Backsplash
/
" max.
3
4
2
/
"
9
16
/
" min.
1
4
flat ledge
* Overall flat ledge behind
backside of cabinet front
** Minimum flat surface required
to fit top surface of cooktop
and downdraft vent cap
E36DD75ESS / 36" Cooktop Cutout Dimensions
36" Cooktops
A
B
C
E36EC65ESS
36"
33
/
"
20
/
3
3
4
8
E36EC70FSS
36"
33
/
"
20
/
"
3
1
4
2
E36GC65ESS
33
/
"
33
/
"
19
/
3
3
7
4
4
8
E36GC70FSS
34
/
"
33
/
"
19
/
1
3
3
2
4
4
E36IC80ISS
36"
33
/
"
20
/
"
3
1
4
2
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.
Countertop Preparation Note:
Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.
*Standard 25" countertop depth may NOT be adequate for
some cooktop/vent installations, especially with backsplash.
Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (PN # 5304444802)
included with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of
rectangular duct recommended, especially when elbows
are required.
When multiple elbows are necessary, ensure a minimum
of 24" of straight duct between any two elbows.
Thermal breaks such as short section of nonmetallic
duct, should be used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or
as few elbows as possible.
Cold weather installations should have additional
backdraft damper installed.
Installing a Downdraft Vent in combination with any gas
cooking surface will affect optimum burner efficiency.
For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web
D
E
"
23
/
" 24
/
"
3
3
16
16
23
/
" 24
/
"
5
5
16
16
" 22
/
" 23
/
"
11
11
16
16
"
22
/
" 23
/
"
9
9
16
16
23
/
" 24
/
"
5
5
16
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents