Electrolux ICON appliances Design Manual page 32

Table of Contents

Advertisement

planning
information
For 36"
gas model:
E36GC76GPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Depth Adjustment
Filler Kit
PN # 903051-9010
9" Stainless
Steel Backsplash
PN # 903048-9010
Black Knobs Kit
PN # 903049-9120
32
cooking
Gas and Electric Slide-In Cooktops
13"
2"
max.
cabinet
depth
Optional 9" stainless
steel backsplash
(attaches to wall)
Side inset
5
/
"
8
1" min. recommended distance between
rear edge of cutout and nearest combustible
surface above countertop
3"
2" dia.
opening to route
power cable
22
/
"
1
8
1
/
"
1
8
24"
max.
1" countertop
overhang
Installation Specifications
Product Weight – 115 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amp
Connected Load (kW Rating) @ 120 Volts = 0.001 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 0.008 Amps
Always consult local and national electric and gas codes.
Cooktop ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Plan installation to access electrical connection, gas
shutoff valve, and pressure regulator from front of cabinet.
Locate 120V grounded outlet in a 4" W x 5" H area on rear
wall, 16" above floor, aligned center with cooktop.
When replacing an existing cooktop with countertop
cutout deeper than 7-1/4" and less than 8-1/2", order
free Depth Adjustment Filler Kit – (PN # 903051-9010).
Cabinet and /or countertop must completely enclose
recessed portion of cooktop. Respect cutout dimensions
and clearances and ensure that all contact surfaces are
solid and level.
Overhead cabinetry should not exceed a 13" max. depth.
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
36" min.
25"
35
/
"
7
8
7
1
/
35
/
" **
2
15
16
2"
Support
2
/
"
1
platform
2
35
/
"
1
8
4" x 4" opening to
route gas supply
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
Allow 1" minimum clearance between rear edge of cooktop
and nearest combustible surface above countertop. If
required clearance can not be maintained, then optional
stainless steel backsplash or noncombustible backsplash
material must be used – otherwise installation will require
custom cabinet and countertop dimensions.
Allow 7" minimum clearance from edge of cooktop to
nearest combustible wall on either side of unit.
Drawers not recommended beneath cooktop.
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 7" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
Cooktop model E36GC76GPS is NOT approved to be
used over any Electrolux ICON
Cooktop model E36GC76GPS (without optional
backsplash) is approved to be used in combina tion with
an Electrolux ICON
Cooktop /Downdraft Vent Countertop Preparation page for
installation specifications.) Proper combination installation
will require cooktop power cord to be relocated to
underside of unit. (For details, refer to 30" & 36" Gas
Slide-In Cooktop Power Cord Relocation Instructions
page or on the web at electroluxicon.com.)
30" min. for
unprotected cabinet
18"
24" min. with
min.
protected bottom
surface
7
/
"
3
4
**Applies only in case
of countertop backwall
7" min. to nearest
combustible wall
(either side of unit)
"
3
/
"
8
" * 35
15
/
" *
35
/
3
16
16
*Both cutout dimensions are
critical to proper cooktop installation.
Due to variations in countertop materials it
is recommended to undercut finished dimension
35
/
" and adjust upon installation of cooktop.
15
16
®
Single Wall Oven.
®
36" Downdraft Vent. (Refer to Slide-In
7
/
"
1
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents